Title (Internal #)DescriptionWork Around (if known)Fixed in Release
Scored=False appearing twice for External Items (D-38152)When the Scored=false setting is set within External Items (part of <itemproc_extension>), the setting is duplicating in the itempool.xml export.Delete the duplicate tag in the itempool.xml.Version 7.2003
Select One within PearsonvueSectionControl not saving (D-38536)When building an exam and attempting to change  a value in the SectionprocExtension > PearsonvueSectionControl from either "true/false" to "Select One" an error message is presenteddelete the section from the template and then re-adding it with the correct information

Version 7.2004

Case scenario returned with questions (D-38205)When a case is added to a section, the display scenario was also added to the items to be displayedDelete the display item before adding to examVersion 7.2004


7.1912 Release

 

Title (Internal #)DescriptionWork Around (if known)Fixed in Release
Secondary LOFT Constraints not allowing QTI to export (D-38123)When secondary LOFT constraints are applied and selected in the build QTI page, you are unable to export QTI.Secondary constraints cannot be applied.Version 7.2001 (Patch)
Pop-up message when clicking on OutcomesProcessingMapped or OutcomesProcessingNda in Build QTI page (D-37819)

When a user clicks on either the OutcomesProcessingMapped or OutcomesProcessingNda nodes in the Build QTI page, a "DataTables warning" pop-up message appears. No impact on saving or exporting exam.

Click on OK in the pop-up message to bypass the pop-up message.Version 7.2003
LOFT Constraints not saving (D-37945)LOFT Constraints not saving when applied to the build QTI page.N/AVersion 7.2001

Using "Get PubMed ID" for journal references causing time out (D-37807)

When a user tries to add a reference to an item and uses the "Get PubMed Reference" to get the information, the system times out and does not bring back the reference informationManually enter the reference data onto the item

Version 7.2001

Selection Node not saving (D-37921)When Selection Numbers (Preselection or Selection) were added to an Exam (either through an exam template or directly from the QTIBuilder View), the Selection Node would not Save.Add the Selection Node immediately prior to exporting the exam on the Builder Screen. No workaround for saving the node prior, however.Version 7.2002
Form Resetting to Template Level (D-38136)A user has an exam with a DT template and modifies the QTI on the BuildQTI page. The user then saves and modifies a value on the Add Exam page (i.e adding a section). Then, the user navigates back to the BuildQTI page. The result is that the data saved on the Add Exam page (i.e the section added) is now gone, and the exam is viewable again.N/AVersion 7.2005

...